Fluorescent Magnetic Powder | 2-3 G / L, Odorless Kerosene |
---|---|
Defoaming Agent | 0.5 - 1 Grams / Liter |
Dispersant | 0.2%, Check The Weight Of The Liquid |
Rust Inhibitor | 0.5%, Check The Weight Of Liquid |
Residual Magnetism Method | I=20D ~ 40D |
Lengthways Magnetic Ampere-turn | AC 0-12000AT, Continuous 2)djustable(power Outage Phase Position Control) |
---|---|
Demagnetization | Remainder Magnetic Less Than 0.3mT |
Distance Of Electrode | 4)0-400mm Adjustable |
Clamp Way | 5)pedal |
Working Way | 6)manual |
Color | Yellow |
---|---|
Ultraviolet Illumination | 5000uW/cm2 |
Power Supply | AC100~240V 50/60Hz |
Packaging Details | Standard export package |
Delivery Time | 1-4days |
Color | Black |
---|---|
Ultraviolet Illumination | >6000u W/ Cm² |
Power Supply | AC100~240V 50/60Hz |
Battery Voltage | 3.7V |
Packaging Details | Standard export package |
Accuracy | ±10% |
---|---|
JCZ-5 | -5~+5Gs |
JCZ-10 | -10~+10Gs |
MD-2 | -20~+20Gs |
JCZ-50 | -50~+50Gs |
Product Name | Magnetic Particle Testing Machine |
---|---|
Magnetization | Circular , Longitudinal , And Resultant Magnetization |
Packaging Details | Standard export package |
Delivery Time | 1-4days |
Payment Terms | T/T, Paypal, Western Union |
Material | ABS |
---|---|
Application | Measurement Of Light Sources And Irradiation Systems, Transmission Measurements, UV Radiation Safety |
UV-365 Probe | λ:(320~400)nm;λP=365nm |
UV-420 Probe | λ:(375~475)nm;λP=420nm |
Measuring Range | (0.1~199.9×103)μW/cm2 Parasitic Light:UV365:less Than 0.02% UV420:less Than 0.02% |
Accuracy | ±10% |
---|---|
Measuring Range | 20mwb |
Basic Error | ±1% |
Sensitivity | 10 μwb |
Display | 3 1/2 LED,Positive And Negative Display Automatically |
Type A1 Magnetic Particle Sensitivity Test Tablet 1.1 The Test Sheets Are Made According To The Req | 50±5μm And 100±10μm |
---|---|
The Edge Length Of The Test Piece | 20±1㎜ |
Circular Artificial Groove Diameter | 10±0.5㎜ |
Cross Artificial Slot Length | 6±0.3㎜ |
Artificial Groove Width | 60 ~ 180μm |